Frymaster 2836 Electric Interface Board Diagnostic Chart, Diagnostic LED Legend, Meter Setting

Models: 2836

1 54
Download 54 pages 31.84 Kb
Page 17
Image 17
1.12 Electric Interface Board Diagnostic Chart

1.12 Electric Interface Board Diagnostic Chart

The following diagram and charts provide ten quick system checks that can be performed using only a multimeter.

 

 

 

3

2

1

 

 

 

 

 

 

6

5

4

 

 

 

 

 

 

9

8

7

 

 

 

 

 

 

12

11

10

 

 

 

 

 

 

15

14

13

 

 

 

K1

 

 

K2

K3

K4

 

 

10

7

4

1

 

10

7

4

1

11

8

5

2

 

11

8

5

2

12

9

6

3

 

12

9

6

3

Note: The sealed relays are replaceable. If a relay fails, the replacement part number is 807-3932.

 

Diagnostic LED Legend

CMP

indicates power from 12V transformer

24

indicates power from 24V transformer

HI

(RH) indicates output (closed) from right latch

 

relay

HI

(LH) not applicable to Ultimate Electric fryers

HT

(RH) indicates output from right heat relay

HT

(LH) not applicable to Ultimate Electric fryers

AL

(RH) indicates output (open) from right latch

 

relay

AL

(LH) not applicable to Ultimate Electric fryers

 

 

Meter Setting

Test

Pin

 

Pin

Results

12 VAC Power

50 VAC Scale

1 of J2

 

3 of J2

12-16 VAC

24 VAC Power

50 VAC Scale

2 of J2

 

Chassis

24-30 VAC

*Probe Resistance

R X 1000 OHMS

11 of J2

 

12 of J2

See Chart

Hi-Limit Continuity

R X 1 OHMS

7 of J2

 

4 of J2

0 - OHMS

Latch Contactor Coil

R X 1 OHMS

8 of J2

 

Chassis

3-10 OHMS

Heat Contactor Coil

R X 1 OHMS

9 of J2

 

Chassis

18-25 OHMS

*Disconnect 15-Pin harness from the computer/controller before testing the probe circuit.