Frymaster EH1721 SERIES ELECTRIC FRYERS, Operator Troubleshooting, Problem, Probable Causes

Models: EH1721 SERIES

1 37
Download 37 pages 23.91 Kb
Page 33
Image 33
5.2.2 Error Messages and Display Problems

EH1721 SERIES ELECTRIC FRYERS

CHAPTER 5: OPERATOR TROUBLESHOOTING

5.2.2 Error Messages and Display Problems

Problem

Probable Causes

Corrective Action

Display is in wrong

 

Computers may be programmed to

 

display in either Fahrenheit or Celsius.

temperature scale

Incorrect display option programmed.

Refer to the computer manual that

(Fahrenheit or

 

shipped with the fryer for instructions

Celsius).

 

 

on changing the display.

 

 

CM III.5

 

Verify that the drain valve is fully

or

 

closed. The fryer will not function if

Digital Controller

Open drain valve or problem with

the drain valve is not fully closed. If

display shows HELP.

the drain valve is fully closed, the

latching circuitry.

CM4-S and KFC-1

problem is within the latching

 

display shows

 

circuitry and is beyond the scope of

OPEN DRAIN

 

operator troubleshooting. Call FASC.

 

 

This display is normal if the fryer

 

 

setpoint has been changed to a lower

 

 

temperature. The display should

 

Fryer is more than 21°F (12°C) above

revert to the normal four dashes when

Display shows hi.

the frypot temperature cools to the

setpoint.

setpoint. If the setpoint has not been

 

 

 

 

changed, this indicates a problem with

 

 

the temperature control circuitry.

 

 

Turn the fryer off and call FASC.

CM III.5

 

 

or

 

This in an indication of a malfunction

Digital Controller

 

display shows hot.

Frypot temperature is more than 410°F

in the temperature control circuitry,

CM4-S and KFC-1

(210°C) or, in CE countries, 395°F

including a failure of the high-limit

(202°C).

thermostat. Shut the fryer down

display shows HI-

TEMP or HI-Temp

 

immediately and call FASC.

 

 

probe failure.

 

 

 

 

This display is normal when the fryer

 

 

is first turned on and may appear for a

 

 

short while if a large batch of frozen

 

 

product is added to the frypot. If the

CM III.5

 

display never goes out, the fryer is not

 

heating. Look for a decimal in the

or

Frypot temperature is more than 21°F

LED display between digits 1 and 2.

Digital Controller

If the decimal is present, the computer

(12°C) below setpoint.

display shows lo.

is calling for heat and is functioning

 

 

 

properly. See Fryer Does Not Heat in

 

 

Control and Heating Problems

 

 

(Section 5.2.1). If the decimal is not

 

 

present, the computer is not calling for

 

 

heat and may be malfunctioning. Shut

 

 

the fryer off and call FASC.

5-4

Page 33
Image 33
Frymaster EH1721 SERIES ELECTRIC FRYERS, Operator Troubleshooting, Error Messages and Display Problems, Probable Causes