Frymaster EH1721 SERIES ELECTRIC FRYERS, Operator Troubleshooting, Problem, Probable Causes

Models: EH1721 SERIES

1 37
Download 37 pages 23.91 Kb
Page 35
Image 35
5.2.4 Built-in Filtration Problems (cont)

EH1721 SERIES ELECTRIC FRYERS

CHAPTER 5: OPERATOR TROUBLESHOOTING

5.2.4 Built-in Filtration Problems (cont)

Problem

 

Probable Causes

Corrective Action

 

C.

Blockage in filter pump.

C. Pump blockages are usually caused

 

 

Test: Close the drain valve and pull

by sediment buildup in the pump

Filter pump won’t

 

due to improperly sized or installed

 

the filter pan out from the fryer.

filter paper and failure to use the

start. (cont)

 

Activate the pump. If the pump motor

crumb screen. Call FASC.

 

 

hums for a short time then stops, the

 

 

 

probable cause is blockage of the

 

 

 

pump itself.

 

5-6

Page 35
Image 35
Frymaster EH1721 SERIES ELECTRIC FRYERS, Operator Troubleshooting, Built-inFiltration Problems cont, Probable Causes