Frymaster FE155 CE Power Requirements, Use copper wire ONLY, suitable for at least 170ºF 75ºC

Models: FE155

1 22
Download 22 pages 29.11 Kb
Page 12
Image 12
Power Requirements

must be oil and water resistant. Make the connections in accordance with the wiring diagram be- low.

3.Install the supplied strain relief, Oflex SKZ21 (8071210), which has a wire range of 15 to 23 mm, and replace the lower back panel and contactor box cover.

4.Install a CE-approved plug rated for a minimum of 32 amps at 415 VAC. In must be a 3-phase, 5-wire type with neutral and ground and be oil and water resistant.

Power Requirements

Use copper wire ONLY, suitable for at least 170ºF (75ºC)

ELECTRIC COOKER MODEL FE155

 

 

 

Amps

 

Minimum

Volts

Phase

kW

(per leg)

 

Wire Size

208

Single

8

38.7

8

220

Single

9

40.9

8

208

3

8

22.3

10

220

3

9

23.6

10

240

Single

10.7

44.6

6

440

Single

9

20.5

10

240

3

10.7

25.8

10

440

3

9

11.8

12

480

Single

10.7

22.3

10

480

3

10.7

12.9

 

12

CE Power Requirements

Use copper wire ONLY, suitable for at least 75ºC

ELECTRIC COOKER MODEL FE155

 

 

 

Amps

Minimum

Volts

Phase

kW

(per leg)

Wire Size

220/400

3

9.8

14.3

4.11 mm