Frymaster manual Calibrate fryer recovery time continued, Monthly, FR 3 M1

Models: FR 3

1 26
Download 26 pages 22.46 Kb
Page 10
Image 10
Calibrate fryer recovery time (continued)

Calibrate fryer recovery time (continued)

4Adjust fryer, if necessary.

If the fryer’s recovery time is not acceptable, check the fol- lowing items on the fryer. If you find any problems, cor- rect them as described.

For electric fryers only, con- firm that the large power plug is properly plugged in. Adjust as necessary.

For gas fryers only, check the seal angle, gravity blade, and standoff. Adjust their place- ment if necessary.

For gas fryers only, check the air flow and combustion air blower. Adjust as necessary.

For gas fryers only, check the condition of the radiant burn- ers.

Refer to trouble shooting guide in Operators manual.

5Check recovery time again.

If Recovery Time is not achieved in the proper time, call the Frymaster Service Hotline for assistance at 1- 800-551-8633.

6Recalibrate all remaining fryers.

Repeat steps 1 through 5 for all remaining fryers.

©McDonald’s Corporation · Planned Maintenance Manual · Revised June 2009

Page 2 of 2