Frymaster HCP Turning Slots OFF, Temperature Display, Temperature Alarms, Sensor-RangeAlarm

Models: HCP

1 30
Download 30 pages 33.93 Kb
Page 10
Image 10

HCP

4.4 Turning Slots OFF

Press the Menu key on a slot until Slot Off is displayed. Release the key and immediately press the Temperature key; the choice is locked in.

4.5 Temperature Display

Press the Temperature key four times and the temperatures and setpoints will be displayed in this sequence:

Top plate temperature

Bottom plate temperature

Top plate setpoint

Bottom plate setpoint

4.6 Temperature Alarms

There are five temperature alarms:

High Temperature

Low Temperature

FDA

Sensor

Rise Time

If an alarm condition occurs, an audible alarm sounds and the display alternates between the product selection and the alarm message. Timers cannot be started if a slot is displaying an alarm message.

4.6.1 High and Low-Temperature Alarms

If the slot temperature is above or below the limits for the product selected, the display will show Slot temp high or slot temp low. An alarm will sound. Press a timer key to turn off the audible alarm. The audible alarm does not sound during initial cabinet startup.

4.6.2 Food and Drug Administration (FDA) Alarm

The FDA alarm indicates the slot temperature is below the preset limit to hold a product. An audible alarm sounds and the alarm message reads Temp Under FDA. Press a timer key to turn off the audible alarm. The message remains until the slot temperature is within limits. Press the timer key to clear the FDA alarm.

4.6.3 Sensor-Range Alarm

The Sensor Fail alarm indicates a sensor temperature value above or below the 90-250°F (32- 121°C) range of the slot. An audible alarm sounds. The displayed message is Sens Alrm. Press a timer key to end the audible alarm. Service is required to correct the sensor alarm.

4-3

Page 10
Image 10
Frymaster HCP operation manual Turning Slots OFF, Temperature Display, Temperature Alarms, High and Low-TemperatureAlarms