1.3 RCI Setup

XSCF> setrci -c init

The command completed successfully

4Connect the main unit and I/O units with RCI cables (see Figure 1.5).

Connect an RCI branching connector to each of the RCI ports, and connect them with RCI cables by using a daisy-chain connection.

Connect an RCI terminating resistor to the branching connector at either end of the RCI connection. Refer to Section 1.3.5, "Connection of RCI."

5Turn on the AC input to all the RCI device which are in the RCI connection.

6Execute the setrci -c set command to make the settings of the host node.

Since the main unit is the first unit, host_no is 1.

XSCF> setrci -c set 1

The command completed successfully

7Execute the setrci -c initconfig command to configure the RCI.

XSCF> setrci -c initconfig

The command completed successfully

8Execute the setrci -c stat command to display the RCI status.

XSCF> setrci -c stat

HOST

address 000101ff Active

LIST

address pwr alm I/F sys-phase ctgry dev-cls sub-cls tm-out 000101ff OFF - ACT power-off host 0001 0b - 003001ff OFF - ACT power-off disk 0400 04 - 003002ff OFF - ACT power-off disk 0400 04 -

The command completed successfully

9Verify that all the RCI device in the RCI connection are incorporated.

C120-E361-04EN