CHAPTER 1 RCI Build Procedure

1.3.3When an RCI I/O unit is added later

RCI Host

Addition

RCI I/O unit

RCI I/O unit

Figure 1.7 When an RCI I/O unit is added later

1Connect the I/O unit to be added with an RCI cable by using a daisy-chain connection (see Figure 1.7).

Connect an RCI branching connector to the RCI port, and then connect it with an RCI cable by using a daisy-chain connection.

Connect an RCI terminating resistor to the branching connector at either end of the RCI connection. Refer to Section 1.3.5, "Connection of RCI."

2Turn on the AC input to all the units which are in the RCI connection.

3Log in to the XSCF Shell.

4Execute the setrci -c addconfig command to configure the RCI.

XSCF> setrci -c addconfig

The command completed successfully

5Execute the setrci -c stat command to display the RCI status.

XSCF> setrci -c stat

 

 

 

 

HOST

 

 

 

 

 

 

 

address 000101ff

 

 

 

 

 

 

Active

 

 

 

 

 

 

 

LIST

 

 

 

 

 

 

 

address pwr alm I/F sys-phase

ctgry

dev-cls sub-cls tm-out

000101ff OFF

-

ACT

--

host

0001

0a

-

003001ff OFF

-

ACT

--

disk

0400

04

-

003002ff OFF

-

ACT

--

disk

0400

04

-

The command completed successfully

6Verify that the added I/O unit is incorporated.

1-8

C120-E361-04EN