A.1 In the Case Where Setrci Command Ended Abnormally and Displayed “Operation Failed Error Status: XX”
Remedy pattarnzPattern A
1Check the RCI setup procedure, the RCI address value and the connection.
1Check the setting of the RCI address and the duplicate of the RCI address by setrci
2Check whether the othr RCI host that doesn't execute the RCI initialization is connected.
2In the case of anomaly, retry RCI setup in correct procedure.
zPattern B
1Check the RCI address value of current unit by setrci
2In the case of anomaly, retry RCI setup in correct procedure.
zPattern C
1Check the RCI address value of current unit and other unit by setrci
2In the case of anomaly, retry RCI setup in correct procedure.
zPattern D
1Check whether 95 and more units of RCI I/O unit (include the External power controller) are not connected.
2When 95 and more units are connected, change the connection configuration to 94 and less units (include the External power controller), and retry RCI setup.
zPattern E
1Replace the XSCF board.
2After the replacement of the XSCF unit, retry RCI setup.
zPattern F
1Check whether RCI address value of the Line selector switch is not duplicated.
2If the duplicate, change the RCI address of the Line selector switch, and retry RCI setup. To change the RCI address of the Line selector switch, refer to its manuals.
zPattern G
Check the state of XSCF, and execute either of the following operations.
When XSCF reboot or redundancy are working, execute the setrci command after these are completed. If the