Appendix A Troubleshooting
A.2 In the Case Where RCI Status of RCI Host Changes From ACTIVE to INACTIVE
Remarks: When this problem has occurred, do not replace the XSCF unit because it is not a failure of the XSCF unit.
This problem is occurred by the mistake of the RCI construction procedure and the RCI connection.
t occurrs when the same RCI address is set and constructed, or, when connecting with the RCI network of the construction of the RCI host that has not been initialized.
Confirm whether to correspond to this problem. The procedure is the following:
1Excute showlogs command, and check whether RCI configuration conflict is generated in error log.
2When that message was generated, check the RCI establishment procedure, the RCI address value and the connection.
3In the case of anomaly, correct the RCI address or the connection of relevant device according to the change procedure of each device.
4Refer to Chapter 1.3.4, "When a RCI Host is added later" and retry RCI establishment.