Appendix A Troubleshooting
This appendix explains how to deal with possible problems during the RCI setup.
zIn the Case Where Setrci Command Ended Abnormally and Displayed “Operation Failed Error Status: XX”
zIn the Case Where RCI Status of RCI Host Changes From ACTIVE to INACTIVE
A.1 In the Case Where Setrci Command Ended Abnormally and Displayed “Operation Failed Error Status: XX”
When the RCI construction by the setrci command ended abnormally and "Operation failed error status: XX" is displayed, the displayed error status code, explanation, and remedy pattern are described to the following table.
Table A.1 The Error Status Code and Explanation
Code | Explanation | Remedy | |
pattarn | |||
|
| ||
00 | Detected the duplicate RCI address. | ||
01 | RCI address of current unit is not configured or false. | ||
02 | Detected the duplicate RCI address of RCI host, or detected the | ||
| undefined RCI address. |
| |
|
|
| |
03 | RCI address of current unit is not configured. | ||
04 | Over maximum entry of RCI table. | ||
05 | Detected anomaly in RCI table receiving. | ||
06 | Detected anomaly in RCI table sending. | ||
07 | Receiving status check from undefined RCI device. | ||
08 | Detected the loss of RCI master. | ||
09 | Detected anomaly of RCI table. | ||
0a | Synchronous time out of RCI table. | ||
0b | Synchronous retry out of RCI table. | ||
0c | Detected anomaly of RCI table. | ||
0d | Failed the version check of RCI table. | ||
0e | Detected anomaly of RCI table. | ||
0f | Detected anomaly in synchronous with RCI Neuron chip. |