CHAPTER 1 RCI Build Procedure

XSCF> setrci -c set 2

The command completed successfully

7Execute the setrci -c addconfig command on main unit B to expand the RCI configuration.

XSCF> setrci -c addconfig

The command completed successfully

8Display the RCI status by executing the setrci -c statcommand on main unit A.

XSCF> setrci -c stat

 

 

 

 

HOST

 

 

 

 

 

 

 

address 000102ff

 

 

 

 

 

 

Active

 

 

 

 

 

 

 

LIST

 

 

 

 

 

 

 

address pwr

alm

I/F

sys-phase

ctgry

dev-cls sub-cls tm-out

000101ff OFF

-

ACT

--

host

0001

0b

-

000102ff OFF

-

ACT

--

host

0001

0b

-

003001ff OFF

-

ACT

--

disk

0400

04

-

003002ff OFF

-

ACT

--

disk

0400

04

-

The command completed successfully

9Verify that the added main unit is incorporated.

1.3.5Connection of RCI

According to the following procedure, connect different units with RCI cables by using a daisy-chain connection.

1Prepare RCI branching connectors and RCI terminating resistors.

All of them are supplied with the main unit.

2Connect the main unit and I/O units with RCI cables (see Figure 1.9 and Figure 1.10.)

1Connect the RCI branching connector (1) to the RCIport on an XSCF unit of the main unit.

2Connect the RCI branching connector and the RCI port of an I/O unit with an RCI cable (2) by using a daisy-chain connection.

1-10

C120-E361-04EN