CHAPTER 1 RCI Build Procedure
1.3.2New setup of two RCI Hosts
RCI | RCI |
Host A | Host B |
RCI I/O unit | RCI I/O unit |
Figure 1.6 New setup of two RCI Hosts
1Log in to the XSCF Shell.
2On main unit A, execute the setrci
XSCF> setrci
HOST
address 000f7fff Inactive
The command completed successfully
3Verify that the RCI address is 000f7fff.
Remarks: 000f7fff is the default value of the RCI address. If the default value is not set, execute the setrci
If the system is powered off, you can use the setrci
XSCF> setrci
The command completed successfully
4In a similar manner, display the RCI status of main unit B to verify that the RCI address is 000f7fff.
5Connect the main unit and I/O units with RCI cables (see Figure 1.6).
Connect an RCI branching connector to each of the RCI ports, and connect them with RCI cables by using a
Connect an RCI terminating resistor to the branching connector at either end of the RCI connection. Refer to Section 1.3.5, "Connection of RCI."
6Turn on the AC input to all the RCI device which are in the RCI connection.