Turn on the scanner before cleaning the following locations, and clean the following rollers while rotating them.

Feed rollers (x 2)

Clean lightly taking care not to roughen the surface of the rollers. Take particular care in cleaning the feed rollers since black debris on the rollers adversely affect the pickup perfor- mance.

Eject rollers (x 2)

Clean lightly taking care not to roughen the surface of the rollers.

Take particular care in cleaning the discharge rollers since black debris on the rollers adversely affect the pickup performance.

To rotate the feed rollers and the eject rollers, press the [POWER] button while holding down the [SCAN] button.

As a guideline, six presses of the [POWER] button make the rollers to rotate one full turn.

 

 

1.

While holding down the [SCAN]

 

 

 

button....

 

SCAN

2.

...press the [POWER] button.

 

POWER

 

 

1

2

The rollers rotate.

DUPLEX

 

 

COLOR

 

.

ATTENTION

Connect the AC adapter and AC cable only when cleaning the feed rollers and eject rollers.