8. Install the pick roller with it’s shaft to the scanner.
Insert the right end of the shaft to the roller bushing (right), and set the shaft to the slot while lowering it.
Pick roller shaft
Pick roller
9. Rotate the roller bushing (left) by rotating it in the direction of the arrow.
ATTENTION
Pick roller | Pick roller bushing |
Pick roller shaft
Make sure that the Pick roller is completely attached. Otherwise, document jams or other feeding errors may occur.