Fujitsu MAE3091LC, MAF3364LP, MAF3364LC, MAG3182LC, MAE3182LC manual 11 Service clearance area

Models: MAE3091LC MAE3182LC MAG3182LC MAF3364LC MAF3364LP

1 133
Download 133 pages 10.27 Kb
Page 64
Image 64
Figure 4.11 Service clearance area

(4)Service clearance area

The service clearance area, or the sides which must allow access to the IDD for installation or maintenance, is shown in Figures 4.11.

[Surface P]

• Cable connection

[Surface P’]

• Setting terminal

• External operator panel connector

• Spindle sync connector

[Surface R]

• Hole for mounting screw

[Surface Q]

• Hole for mounting screw

Figure 4.11 Service clearance area

(5)External magnetic field

The drive should not be installed near the ferromagnetic body like a speaker to avoid the influence of the external magnetic field.

(6)Leak magnetic flux

The IDD uses a high performance magnet to achieve a high speed seek. Therefore, a leak magnetic flux at surface of the IDD is large. Mount the IDD so that the leak magnetic flux does not affect to near equipment.

(7)Others

A hole or screw portion as shown in Figure 4.12 is used for adjusting air pressure balance between inside and outside the DE. Do not fill with a seal or label.

Seals on the DE prevent the DE inside from the dust. Do not damage or peel off labels.