Fujitsu MAF3364LC Cable connector requirements, 2 Recommended components for connection, Figures

Models: MAE3091LC MAE3182LC MAG3182LC MAF3364LC MAF3364LP

1 133
Download 133 pages 10.27 Kb
Page 81
Image 81

b.–WTP: Input signal (CN2-9, 10 pin)

By connecting the CN2-10 pins to the GND, writing operations into the IDD disc media are set to disable.

4.3.3Cable connector requirements

Table 4.2 lists the recommended components cable connection.

Table 4.2 Recommended components for connection

Applicable

 

Name

Par number

Manufacturer

Reference

 

(Figures 4.25

model

 

 

 

 

 

and 4.30)

 

 

 

 

 

LP/MP

SCSI cable (CN1)

Cable socket

786090-7

AMP

S1

 

 

(closed-end type)

 

 

 

 

 

Signal cable

 

 

Power supply cable

Cable socket

1-480424-0

AMP

S2

 

(CN1)

housing

 

 

 

 

 

Contact

60619-4

 

 

 

 

Cable

60617-4

 

 

 

External operator

Cable socket

FCN-723J012/2M

Fujitsu Limited

S3

 

panel (CN1)

housing

 

 

 

 

 

Contact

FCN-723J-G/AM

Fujitsu Limited

 

 

 

Cable

AWG26 to 34

 

 

 

External operator

Cable socket

FCN-723J016/2M

Fujitsu Limited

S4

 

panel (CN2)

housing

 

 

 

 

 

Contact

FCN-723J-G/AM

Fujitsu Limited

 

 

 

Cable

AWG28

 

 

LC/MC

SCSI connector

Connector

787311-1

AMP

 

 

(CN1)

 

 

 

 

(1)SCSI cable

See Section 1.3, “Physical Requirements”, and Section 1.4, “Electrical Requirements”, in SCSI Physical Interface Specifications.

(2)Power cable

IDDs must be star-connected to the DC power supply (one to one connection) to reduce the influence of load variations.

(3)DC ground

The DC ground cable must always be connected to the IDD because no fasten terminal dedicated to SG is provided with the IDD. Therefore, when SG and FG are connected in the system, it is necessary to connect SG and FG at the power supply or to connect SG of the power supply to FG of the system.

4 - 28

C141-E064-03EN

Page 81
Image 81
Fujitsu MAF3364LC, MAF3364LP, MAG3182LC manual Cable connector requirements, 2 Recommended components for connection, Figures