Fujitsu MB39A104 manual H ON Power ON, L OFF Standby mode, V TH = 1.4, Applicationexample

Models: MB39A104

1 36
Download 36 pages 60.14 Kb
Page 22
Image 22
■APPLICATIONEXAMPLE

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Step-

 

 

MB39A104

 

R10R11 INE1

 

 

 

 

 

 

 

 

 

down

 

 

 

 

 

 

 

 

 

VCCO

 

 

A

VO1

A

 

 

 

10

VREF

Error

 

 

 

CH1

 

 

 

 

 

L priority

 

 

1

 

 

 

(5.0 V)

150 kΩ 56 kΩ

 

 

 

 

Q1

L1

CS1 10 A

Amp1

PWM

 

 

 

 

 

 

R9

 

 

Drive1

 

 

 

15 F

 

 

CH1 ON/OFF signal

68 kΩ

11

 

+

+ Comp.1

 

OUT1

 

 

 

 

 

 

 

 

+

 

 

 

 

 

 

 

 

(Hiz : ON, L : OFF)

C16

 

220

R8

 

+

 

Pch

3

+

 

D1

+

 

 

1.24 V

 

 

 

 

 

 

0.1

 

 

L priority

 

 

 

 

 

C2

C3

 

C4

 

 

F

 

kΩ

 

 

 

 

 

 

 

 

F

 

 

 

C12

9

 

 

 

IO = 200 mA

 

10

10

 

82

 

 

 

 

 

 

 

F

F

 

 

APPLICATIONEXAMPLE

 

1000 pF FB1

 

 

 

at VCCO

= 12 V

VS1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Current

 

4

R4

 

 

 

 

 

 

 

 

 

 

 

Protection

+

5

 

 

 

 

 

 

DTC1

 

 

 

Logic

 

 

 

 

 

 

 

 

 

 

 

 

 

2.7 kΩ

 

Step-

 

 

 

 

 

6

 

 

 

 

 

 

ILIM1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

down

 

 

 

 

R15R16 INE2

 

 

 

 

 

 

C11

 

 

B

VO2

 

B

 

 

Ω

15

VREF

Error

L priority

 

 

CH2

 

 

 

100 kΩ 13 k

 

 

 

 

0.1 F

 

Q2

L2

(3.3 V)

 

 

CS2 10 A

Amp2

PWM

 

 

 

 

 

 

CH2 ON/OFF signal

R14

 

 

Drive2

OUT2

 

 

15 F

 

 

 

68 kΩ

14

 

+

+ Comp.2

 

 

 

 

 

 

(Hiz : ON, L : OFF)

C17

 

 

 

+

+

 

 

Pch

22

 

 

 

 

 

 

 

220

R13

 

 

 

 

+

 

D2

+

 

 

 

0.1

 

kΩ

 

1.24 V

 

 

 

 

 

 

C6

C7

 

C8

 

 

VIN

F

 

16

L priority

 

 

 

 

 

 

F

 

 

C14

 

 

 

IO = 200 mA

 

10

10

 

82

 

(7 V to 19 V)

1000 pFFB2

 

 

 

 

F

F

 

 

 

 

 

 

 

 

19

 

 

 

at VCCO

= 12 V

VS2

 

 

 

 

 

 

 

 

 

DTC2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H:

H priority

 

Current

 

21

R5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

at SCP

SCP

 

Protection

+

20

 

 

 

 

 

 

 

 

 

 

 

Comp.

 

Logic

 

 

2.7 kΩ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ILIM2

 

 

 

 

 

 

 

 

 

 

 

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.1 V

 

 

 

VH

 

 

 

 

 

 

 

 

 

 

 

 

 

H:

 

VCC 5 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

at OCP

 

2

 

 

 

 

 

 

 

 

 

 

 

SCP

 

 

 

 

VH

 

 

 

 

 

 

Charging

 

 

 

 

 

 

 

Bias

 

 

 

 

 

 

 

 

 

 

Logic

 

 

 

 

Voltage

GNDO

 

 

 

 

 

 

current (1 mA) CSCP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

2.5 V

Error Amp Power Supply

23

 

 

 

 

 

 

 

 

 

C21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.5 V

 

 

 

 

 

 

 

 

1000 pF

 

UVLO

 

 

 

 

VCC

 

 

 

 

 

 

 

 

 

 

 

 

H:

 

Error Amp Reference

7

C10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UVLO release

bias

1.24 V

 

CTL

0.1 F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power

 

 

 

 

 

 

 

 

 

 

 

OSC

 

VREF

 

24

 

 

 

 

 

 

 

 

 

 

 

accuracy

VR1ON/OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

± 1%

 

 

CTL

H : ON (Power ON)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12 13

5.0 V 17

 

 

18

L : OFF (Standby mode)

 

 

 

 

 

 

 

 

RT

CT

VREF

 

GND

VTH = 1.4 V

 

 

 

 

 

 

 

 

 

R1

C1

C20

 

 

 

 

 

 

 

 

 

 

 

 

 

24 kΩ

100 pF

0.1 F

 

 

 

 

 

 

 

 

 

Page 22
Image 22
Fujitsu MB39A104 manual H ON Power ON, L OFF Standby mode, V TH = 1.4, Applicationexample