| 5.3 Host Commands | |
|
| Table 5.26 Action code |
|
|
|
|
|
|
|
| Code(hex) | Function | Data transfer |
|
|
|
|
|
|
| 0000 | Reserved | - |
|
|
|
|
|
|
| 0001 | Not supported | - |
|
|
|
|
|
|
| 0002 | WRITE SAME | Write |
|
| See Table 5.27. |
| ||
|
|
|
| |
|
|
|
|
|
| 0003 | ERROR RECOVERY CONTROL | - |
|
| See Table 5.28. |
| ||
|
|
|
| |
|
|
|
|
|
| 0004 | FEATURE CONTROL | - |
|
| See Table 5.29. |
| ||
|
|
|
| |
|
|
|
|
|
| 0005 | SCT DATA TABLE | Read |
|
| See Table 5.30. |
| ||
|
|
|
| |
|
|
|
|
|
| 0006 to BFFF | Reserved | - |
|
|
|
|
|
|
| C000 to FFFF | Vender specific | - |
|
|
|
|
|
|
Table 5.27 WRITE SAME (1/2)
Byte(hex) | Name | Value | Description |
|
|
|
|
00, 01 | Action Code | 0002h | WRITE SAME |
|
|
|
|
|
|
| Repeat Write Pattern |
|
| 0001h | It initializes it by data pattern of 32bit specified with |
|
|
| byte |
|
|
|
|
|
|
| Repeat Write data block |
02, 03 | Function Code | 0002h | It initializes it by data pattern of 1sct transfer by the |
|
| ||
|
|
| SCT Write data. |
|
|
|
|
|
| 0101h | Repeat Write Pattern Foreground |
|
|
|
|
|
| 0102h | Repeat Write data block Foreground |
|
|
|
|
04 to 0B | LBA | (8 byte) | Start LBA |
|
|
|
|