5.3 Host Commands
| Table 5.31 HDA Temperature | |
|
| |
Byte(hex) | Contents | |
|
| |
00, 01 | Format Version | |
|
| |
02, 03 | Sampling Period | |
Frequency of sampling each set time of temperature log. | ||
| ||
|
| |
04, 05 | Interval | |
Time of temperature log of interval (min) | ||
| ||
|
| |
00 | Max Operation Limit (°C) | |
|
| |
07 | Over Limit (°C) | |
|
| |
08 | Min Operation Limit (°C) | |
|
| |
09 | Under Limit (°C) | |
|
| |
0A to 1D | Reserved | |
|
| |
1E, 1F | Number of logs that can be recorded in temperature log | |
|
| |
20, 21 | Index of temperature log | |
|
| |
| Temperature log (478 data) | |
| Entry 80h temperature log at Power cycle and default value is | |
| 80h. | |
22 to 1FF | 022h: Temp Log No.0 | |
| ||
| 023h: Temp Log No.1 | |
| to | |
| 1FFh: Temp Log No.478 | |
|
|