5.3 Host Commands

Error reporting conditions

(1)An undefined code is specified in the FR or SC field (ST = 51h, ER = 04h).

(2)A SATA communication error occurred (ST = 51h, ER = 14h).

At command issuance (Shadow Block O registers setting contents)

CM

1

1

1

 

0

1

 

1

 

1

1

 

 

 

 

 

 

 

 

 

 

 

 

DH

x

x

x

 

x

 

 

 

xx

 

 

 

 

 

 

 

 

 

 

 

 

 

CH

 

 

 

 

 

xx

 

 

 

 

CL

 

 

 

 

 

xx

 

 

 

 

SN

 

 

 

 

xx or *5

 

 

 

 

SC

 

 

 

 

xx or *1 to *5

 

 

 

 

FR

 

 

 

[See Table 5.34]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

At command completion (Shadow Block Registers contents to be read)

ST

 

 

 

Status information

 

 

 

 

 

 

 

 

 

DH

x

x

x

 

x

 

xx

 

 

 

 

 

 

 

 

CH

 

 

 

 

xx

 

CL

 

 

 

 

xx

 

SN

 

 

 

 

xx

 

SC

 

 

 

 

xx

 

E

 

 

 

Error information

 

 

 

 

 

 

 

 

 

C141-E280

5-121