SPARC Enterprise M8000/M9000 Servers Product Notes 13
RTIF1-
071116-001
After using the addfru(8) or replacefru(8)
command to hotplug a CMU, further DR
operations might fail with a misleading
message regarding the board being
unavailable for DR.
When performing the addfru(8) and
replacefru(8) commands, it is mandatory to
run diagnostic tests. If you forget to run the
diagnostic tests during
addfru(8)/replacefru(8) then either run
testsb(8) to test the CMU or remove the
CMU/IOU with the deletefru(8) command
and then use the addfru(8) command with the
diagnostic tests.
RTIF1-
071116-002
Permanent memory DR operation during
XSCF failover might cause domain panic.
Do not start an XSCF failover while a DR
operation is running. Wait for a DR operation
to finish before starting the failover. If you start
the failover first, wait for the failover to finish
before starting the DR operation.
RTIF1-
071116-003
Using the XSCF Web, when you selected COD,
codusage details cannot be displayed correctly.
Use showcodusage(8) command to display
the codusage.
RTIF1-
071116-004
When Internet Explorer 7 browser is used, the
License key deletion cannot be executed on the
BUI COD page.
Use deletecodlicense(8) command to
delete a license key. Or use other browsers:
• Microsoft Internet Explorer 6.0
• Firefox 2.0 or later
• Netscape Navigator 7.1 or later
RTIF1-
071116-005
While system power on, when the XSCF
switching performed by switchscf(8)
command, PANIC might be generated in XSCF
before it switches, and "SHUTDOWN timeout"
may be stored in the error log.
None available at this time. This message can
be safely ignored.
RTIF1-
071116-006
While XSCF is running, error message of
"hang-up is detected" might be displayed to
XSCF console, and XSCF may reboot.
Check that XSCF is started. If not started, use
the rebootxscf(8) command to restart XSCF,
or stop all the domains and then execute the
system power off/on (AC OFF/ON). To turn
on the system power that you turned off, wait
at least 30 seconds before power-on.
RTIF1-
071126-002
When the server is being installed, and the
mainline switch is turned on for the first time,
these error messages might be displayed:
PSU shortage
XSCF watchdog timeout
XSCFU hang-up is detected
XSCF process down detected
Turn off the system AC power, then turn it on
again.
When the error log is displayed again, turn off
the system AC power, then turn it on again. To
turn on the system power that you turned off,
wait at least 30 seconds before power-on.
TABLE3 XCP Issues and Workarounds (Continued)
ID Description Workaround