SPARC Enterprise M8000/M9000 Servers Product Notes 29
13. Wait until XSCF firmware reaches the ready state.
This can be confirmed when the READY LEDs of XSCF_B#0 and XSCF_B#1 remain
lit.
14. Log in on to XSCFU#0 using a serial connection or LAN connection.
15. Confirm no abnormality o ccurred by using showlogs error -v and
showstatus(8) commands.
Note – When you execute the showlogs(8) command, the following two error logs
regarding the standby XSCF are displayed. These error logs can be safely ignored.
FRU: /XSCFU_B#1
Msg: Failed to decide active XSCFU (step1 timeout)
FRU: /XSCFU_B#1
Msg: Failed to decide active XSCFU (step2 timeout)
If you encounter any hardware abnormality of the XSCF contact a certified service
engineer.
16. Confirm and update the imported XCP image again.
Specify the XCP version to be updated. In this example, it is 1060. XSCF#1 will be
updated, and then XSCF#0 updated, again.
When the firmware update for XSCF#0 is complete, XSCF#1 is active.
17. Log in to XSCFU#1 using a serial connection or LAN connection.
18. Confirm completion of the update by using the showlogs event command.
Confirm no abnormality is found during the update.
XSCF> showlogs error -v
XSCF> showstatus
XSCF> flashupdate -c update -m xcp -s version
XSCF> showlogs event