SPARC Enterprise M8000/M9000 Servers Product Notes 19
6511374 Unexpected error messages may be displayed
on console after changing the system
configuration.
Example:
WARNING: Translation error source
/LSB0/B0/0, PA 3c000000000, target
/LSB0/B0/20000000
This message can be safely ignored.
6515648 "Replumb Failed" error appears when
dr@0:SB1::memory fails.
Once the DR operation is complete, it can be
plumbed up manually.
Example steps to re-plumb the interface
manually:
# ifconfig interface plumb xxx.xxx.xxx.xxx
netmask + broadcast + up
# ifconfig interface group group-name
# ifconfig interface addif xxx.xxx.xxx.xxx
-failover deprecated up
This workaround assumes that the
/etc/hostname.interface file is correctly
configured for the IPMP group and does not
need any modification. The IP addresses used
in the example above should match what was
previously used and what matches the
/etc/hostname.<interface> file.
6516135 Ap_Id format and devices may not be shown
correctly by cfgadm(1M).
Use the following operations to display all of
the PCI slots.
1) devfsadm (at Solaris prompt)
2) cfgadm
6519290 Large amounts of I/O on swap devices can
cause the system to appear hung by over
welling the I/O system. The amount of I/O
required can be generated through a number
of ways, eg memory shortage, heavy use of
/tmp etc.
Set the following to /etc/system and then
reboot the domain:
set maxfastscan=0x2000
6520990 Domain may cause a panic when
deleteboard(8) command for kernel board
by using Dynamic Reconfiguration (DR).
To mask this error, add the following entry to
the /etc/system file.
set drmach:fmem_timeout = 30
This bug has been fixed in Solaris 10 8/07.
TABLE4 Specific Issues and Workarounds Concerning Solaris (Continued)
CR ID Description Workaround