External buzzer (option)

The optional external buzzer provides a louder alert when the guard alarm is violated.

External buzzer

Type: OP03-168

Code No.: 008-462-790

Name

Type

Code no.

Qty

 

 

 

 

MJ-XH

03-2022 (2-3P)

008-463-540

1

connector

 

 

 

 

 

 

 

Buzzer

80-0641

008-462-800

1

assy.

 

 

 

 

 

 

 

1.Unfasten screws and connector nuts to remove the rear cover from the display unit.

2.Place the rear cover on a workbench, out side up. Remove the plastic hole cover from the location shown in Figure 19 with a Phillips screwdriver and a hammer. Remove burrs from the hole with a fine file or sandpaper.

3.Insert the MJ connector (supplied as option) in the hole made at step 2 as shown in Figure 17. And then fasten the connector nut with 0.76-0.78 Nm torque.

4.Plug in the XH connector at the end of above connector into J6 on the DU Board.

5.Fasten screws and connector nuts to reassemble the display unit. Torque should be between 0.76-0.78 Nm.

6.Fasten the buzzer near the display unit (within 1 m) with two tapping screws (3X15 or 3X20; local supply).

7.Attach the connector from the external buzzer to the MJ connector.

Connector nut

Display unit, rear cover

Connector gasket

MJ connector

XH connector

(to J6 on the DU Board)

Figure 17 Fixing MJ-XH connector assembly

60 mm

50 mm

2-φ3.5

Figure 18 External buzzer

External Buzzer

Remove hole cover with Phillips screwdriver and hammer. Remove burrs from hole with fine file or sandpaper. Attach connector (supplied as option).

J6 located at right side of shield case under the rear panel.

Figure 19 Display unit, rear view

9

Page 15
Image 15