5.4 Self Test

The self test facility checks the keyboard, ROM and RAM for proper operation.

1.Press the [MENU] key.

2.Select “OTHER MENU”.

3.Select “23. Self Test” and press the [ACQ/ ENTER] key. The following display appears.

 

 

[Self Test]

 

Key tset: Press each key and

 

check on-screen indication

 

lights.

ARP-10 TEST

 

 

 

 

 

 

 

 

 

 

 

 

ROM

OK 18990871xx

 

 

 

 

 

 

RAM

OK

 

 

 

 

 

 

 

 

SPEED

OK NAV 0.0KT

 

 

 

 

 

 

 

COURSE OK

167.6θ

 

 

 

 

 

 

 

 

 

 

TRIGGER NG

 

 

 

 

 

 

 

 

VIDEO

NG

 

 

 

 

 

 

 

 

BP

OK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HP

OK

 

 

 

 

 

 

 

 

MIN-HIT

 

0003

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SCAN-TIME

0854

 

 

 

 

 

 

 

MAN-ACQ

 

00

 

 

 

 

 

 

 

AUTO-ACQ

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FE-DATA1

0000

 

 

 

 

 

 

 

FE-DATA2

0000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Program No. : 0359222-XX.XX

ROM : OK

RAM : OK

EEPROM : OK

Hours in use : 000006.9H

Tx hours: 000001.1H

OK

<Press MENU for OTHERS menu>

XX: Program Version No.

Figure 5-1 Self test screen

4.The ROM and RAM are automatically checked. If NG (No Good) appears to the right of ROM or RAM indication, contact your dealer for advice. ARP-10 TEST results appear only when optional ARP-10 board is mounted.

5.To check the keyboard. Press any key except the omnipad, ACQ.and power keys. Its corresponding location on the display lights in black if the key is operating properly.

6.Press the [ACQ] key to check the display circuit. The following pattern should appear.

Figure 5-2 Test pattern

7.Press the [MENU] key to show the brilliance adjustment menu.

8.To escape from the selftest, press the [MENU] key.

5.5Life Expectancy of Magnetron

The following table shows the life expectancy of the magnetrons.

Table 5-3 Life expectancy of magnetrons

Model

Type

Code no.

Life

expectancy

 

 

 

 

 

 

 

 

E3571

000-146-867

 

 

 

 

 

1932 M2

MG4004

000-158-895

 

 

 

 

MAF1421B

000-158-786

2,000-3,000

 

 

 

 

-10

 

 

 

hours

 

 

 

 

 

000-146-871

(Including

 

 

 

 

MAF1422B

 

stand-by)

 

000-158-788

 

 

1942 M2

 

 

 

-10

 

 

 

 

 

 

 

 

 

MG4006

000-150-838

 

 

 

 

 

5-3

Page 35
Image 35
Furuno 1942 MARK-2 manual Self Test