Furuno DS-80 MAINTENANCE, Troubleshooting, Maintenance, Preventive maintenance, Fuse replacement

Models: DS-80

1 40
Download 40 pages 51.13 Kb
Page 22
Image 22

3 MAINTENANCE, TROUBLESHOOTING

WARNING

ELECTRICAL SHOCK HAZARD

Do not open the equipment.

Only qualified personnel should work inside the equipment.

3.1Maintenance

3.1.1 Preventive maintenance

Check the following points regularly to maintain performance.

Check that the connectors on all units of the system are firmly fastened and free of rust. Clean if soiled or corroded.

Check that all ground wires are tightly fastened.

Dust and dirt on the display unit including the screen may be removed with a soft cloth. Do not use chemical cleaners to clean the display unit; they can remove paint and markings.

3.1.2 Transducer maintenance

Marine life (barnacles, etc.) adhering to the transducer face will reduce sensitivity. Periodically remove any marine life from the transducer face with fine sandpaper or a piece of wood.

CAUTION

Do not paint the transducer.

Painting will affect performance.

3.1.3 Fuse replacement

Fuses in the units of the system protect the electrical circuitry from burning by overcurrent. If the equipment cannot be energized check the fuse in the power cable connected to the display unit. Locate the cause before replacing the fuse.

Unit

Rating,

Type,

Location

Qty

Code No.

 

 

 

 

FGMB 1A

Fuse

Display

1A,

125 VAC,

holder in

Unit

2 pcs.

000-114-8

power

 

 

05

cable

 

 

FGBO 3A

Inside

Distribution

3A,

250 VAC

unit

Box

2 pcs.

000-549-

 

 

 

021

 

 

 

FGBO 1A

 

Transceiver

1A,

250 VAC,

 

Unit

2 pcs.

000-549-

 

 

 

019

 

CAUTION

Use the proper fuse.

Use of a wrong fuse can cause fire or equipment damage and void the warranty.

14

Page 22
Image 22
Furuno DS-80 MAINTENANCE, Troubleshooting, Maintenance, Preventive maintenance, Transducer maintenance, Fuse replacement