1.4 Processor Unit

Mounting considerations

When selecting a mounting location, keep in mind the following points:

Locate the processor unit away from heat sources because of heat that can build up inside the cabinet.

Locate the unit away from places subject to water splash and rain.

Leave sufficient space at the sides and rear of the unit to facilitate maintenance, referring to the outline drawing.

A magnetic compass will be affected if the processor unit is placed too close to it. Observe the compass safe distances on page ii to prevent interference to a magnetic compass.

Mounting procedure

Fix the unit with four M6 bolts or self-tapping screws.

 

 

2-φ7 FIXING HOLES

385

#50

 

 

370±1

25

410

340±1

380

#Minimum recommended service space

350±1

7

2-FIXING NOTCH

 

Mounting dimensions for processor unit

Upper case assy.

Note: If you fix the unit with the cable entry up, do not unfasten the screw (M3x10) that fastens the upper case assy. and lower case assy. of the processor unit.

Lower case assy.

Do not unfasten this screw.

1-15