Furuno FAR-2157 installation manual Signal cable RW-9600 Between antenna unit and processor unit

Models: FAR-2157

1 111
Download 111 pages 35.77 Kb
Page 36
Image 36

Cable fabrication for the cables connected to the 03P9342 board

Signal cable RW-9600 (Between antenna unit and processor unit)

Vinyl sheath

Armor

Shield

60

450

5

Vinyl tape

Expose cores, and then

 

 

wind shield around armor.

 

 

6

 

 

 

14 5 9

 

Coaxial cable

Conductor

Fasten cable clamp here.

 

Fold back shield.

 

Coaxial cable

 

 

Power cable TPYC-1.5

Armor

60: Peel paint

L: According to location of connector.

6

L

Cables for optional equipment (use TTYCS-1 or TTYCS-4, or equivalent)

Armor

60: Peel paint.

 

Armor

Shield

Sheath

 

 

 

 

 

 

 

 

 

 

 

Shield

L= Depends on equipment

 

L

 

φ = 10.1 mm Conductor

connected. Measure at

 

5

 

S = 0.75 mm2

processor unit.

 

 

φ = 1.11 mm

 

 

 

TTYCS-1

 

 

 

 

Vinyl tape

Expose cores, and then

 

Armor

wind shield around armor.

 

 

 

 

6

Fasten cable clamp here.

φ = 16.3 mm

Sheath

Shield

 

Conductor

S= 0.75 mm2 φ = 1.11 mm

TTYCS-4

2-12

Page 36
Image 36
Furuno FAR-2157 installation manual Signal cable RW-9600 Between antenna unit and processor unit, Power cable TPYC-1.5