2.7Setting Functions (FUNCTIONS menu)

See menu description below for detailed information.

1.Press the [MENU] key to open the main menu.

2.Press ! or " to select FUNCTIONS.

3.Press the [ENT] key to display the FUNCTIONS menu.

Figure 2-14 FUNCTIONS menu

4.Press ! or " to select menu item and press the [ENT] key.

5.Press ! or " to select option desired.

6.Press the [ENT] key to register your selection.

7.Press the [MENU] key twice to close the menu.

2.7.1FUNCTIONS menu description

RCV NOTIFY: The raw NAVTEX signal can be monitored through the monitor speaker by turning RCV NOTIFY on. The default setting is OFF.

RCV ALARM: The audible alarm may be generated when message type A, B, D or L is received. The default setting is ON.

KEY BEEP: The equipment can emit a beep tone when a control is operated. The default setting is ON.

ERROR RATE: When character error occurs due to noise interference during signal propagation, erroneous character is displayed as “”.

Error Rate means character error rate and is calculated as followed:

Error Rate = number of erroneous characters total number of characters received 100 (%) (Total number of characters includes space, line feed, carriage returns, etc.)

When the character error rate is within the percentage you set (0-39%), the NX-300 displays the message and stores it. When it exceeds the percentage you set, the NX-300 neither displays nor stores the message. You may set the threshold level of character error rate as desired and the default setting is 33%.

2-5

Page 27
Image 27
Furuno NX-300 manual Setting Functions Functions menu, Functions menu description