5. MAINTENANCE &

TROUBLESHOOTING

WARNING

Do not open the equipment.

Only qualified personnel should work inside the equipment. Further, watertightness may be reduced.

5.1Maintenance

Check the following points regularly to maintain performance:

Check that connectors on the rear panel are firmly tightened and free of rust.

Check that the ground system is free of rust and the ground wire is tightly fastened.

Check that battery terminals are clean and free of rust.

Check the antenna for damage. Replace if damaged.

Dust and dirt on the keyboard and display screen may be removed with a soft cloth. Do not use chemical cleaners to clean the equipment; they may remove paint and markings.

5.2Diagnostic Test

The diagnostic test checks ROM, RAM, data port, battery, keyboard and LCD for proper operation and displays program numbers.

1.Press the [MENU] key to open the main menu.

2.Press the ! or " to select SYSTEM MENU.

3.Press the [ENT] key to show the SYSTEM MENU.

4.Press ! or " to select TEST.

5.Press the [ENT] key. You are asked if you are ready to start the test.

Figure 5-1 TEST window

6.Press the # to select YES.