5.Press the [AUTO] and [+] keys together more than two seconds.

AUTO TRUE CALIB STATUS

CALIBRATION

AUTO TRUE

INTEGRATED HEADING SENSOR

PG-1000

Figure 5 Key and LEDs

After the TRUE, CALIB and STATUS LEDs light and AUTO LED blinks, rotate the equipment 360º slowly, keeping it uplight. If three LEDs are lighting, the mounting location is suitable

AUTO TRUE CALIB STATUS

: On

: Blinking

Figure 6

If one or more LED is off, the mounting location is not suitable. Try to change the location, and do step 5 again.

6.Press the [AUTO] and [TRUE] keys to- gether to return to the normal mode. The STATUS LED blinks while the sensor is be- ing calibrated and lights steady when the calibration is completed. Do not operate the sensor while the LED is blinking; calibra- tion will be incomplete.

1.3Mounting

1.Fix the sensor by using screws and washers (supplied). The size of the fixing hole is ø 4.5 mm.

Ship's bow

Bow mark

fixing hole

130

65

 

.5 5

141 152

This line should be at right angles to the fore and aft line.

Material: Brass

o All dimensions in mm.

o For added support, use nuts, bolts and washers.

o Secure sufficient clearance around the sensor for maintenance and checking.

Figure 7 Mounting the PG-1000

Note: Do not overtighten the screws or bolts; the sensor may crack.