G-SPEED Product Guide
4.Accept all other default settings on the Quick Create page. To complete the process and create the RAID/Volume Set, check the “Confirm The Operation” check box and hit the “Submit” button. This will begin the initialization process.
5. The initialization process can take from a few seconds to over 3 hours depending on the RAID level chosen and the size of the array.
Drives | RAID 0 | RAID 3 |
(6) 250GB Drives | <1min | 1h 18m |
(6) 500GB Drives | <1min | 2h 49m |
(6) 750GB Drives | <1min | 3h 19m |
6. Once the initialization is complete, reboot your computer system and the array will appear as a blank disk, ready to be formatted. Refer to your system documentation for instructions on formatting
8.4Deleting a RAID set
1.Select “Delete Raid Set” under the “RaidSet Functions” on the left navigation bar. The following screen will appear:
Check the “Confirm The Operation” checkbox and hit the “Submit” button.
WARNING: THIS OPERATION WILL DELETE THE RAID SET AND ANY DATA ON THE
The
8.2for details on configuring a RAID Set on
9.HARDWARE MONITORING
1.Should hardware fail in your
A.The Status LED will flash:
Status LED
Flashing
B. An audible alarm will sound (audible alarm is enabled by default – to disable see Section 10.1)