Gaggenau AH 600-190 manual Important notes, For your safety

Models: AH 600-190

1 19
Download 19 pages 47.56 Kb
Page 4
Image 4
1. Important notes

1. Important notes

1.1 For your safety

Damaged appliances must not be operated.

The appliance must only be connected by an authorised specialist, paying attention to the relevant regulations of the power supply companies and the regional construction regulations.

Also observe the assembly instructions!

Connecting cables must not come into contact with hot cooking surfaces.

Do not operate the extractor hood without inserted lamps.

Never operate the appliance without a grease filter.

Hazardous or explosive substances and vapours must not be extracted!

The user is responsible for expert use and the perfect condition of the appliance.

Only ever operate the appliance under super- vision.

Caution! Over-greased filters are a fire risk! Only ever deep-fry under the extractor under constant supervision. Pay attention to cleaning the grease filter on a regular basis.

Fire risk! Do not flambé meals under the extractor hood!

Operation of the extractor hood above a hearth for solid fuels (coal or wood etc.) is only partly permitted.

Gas appliances may only be used under the extractor hood when pots and pans are placed on them!

When using more than 3 gas-operated rings at the same time, please operate the extractor hood at level 2 or higher. This prevents a build- up of heat in the appliance.

Do not place any heavy objects on the appli- ance; this will have a detrimental effect on functioning.

Do not clean the appliance with a steam cleaning apparatus or with water pressure because this poses a risk of short-circuits.

Isolate the appliance from the mains during every maintenance operation. To do this, remove the mains plug or actuate the correspon- ding fuse.

If the mains plug is not accessible, the appliance must be deenergised by means of the domestic installation fuse.

Repairs must be carried out by authorised specialists, thus ensuring electrical safety.

No warranty claims can be lodged in the event of damage caused by failure to observe these instructions.

Adequate incoming air must be ensured if a wood, coal, gas or oil heater or an open hearth is operated in the same room as the one in which the hood is installed.

Safe operation is possible whenever the partial vacuum in the place where the firing equip- ment is installed does not exceed 4 Pa

(0.04 mbar). This can be achieved whenever the air needed for combustion is able to enter through openings that cannot be sealed, for example in doors, windows, incoming/exhaust air wall boxes or other technical means.

If the appliance is to be operated only with the window open (to ensure adequate incoming air), you can use the window switch.

A switch (normally open) is fitted on the window. On the appliance, this switch is connected to the window switch terminal on the main electronics. The appliance can now only be operated when the window is open.

Important: the window switch must only be connected by an authorised specialist.

Note: The light function works without restriction.

After a power failure, the extactor will not go on again automatically. You can recommence operation by turning a knob or by pressing any key.

Technical modifications reserved.

3

Page 4
Image 4
Gaggenau AH 600-190 manual Important notes, For your safety