air:Exhaust

Flexible aluminium pipes, corrosion-protected sheet metal pipes and exhaust air pipes whose material conforms to fire B1 in accordance with DIN 4102 can be used. Exhaust air pipes should have a nominal diameter of 150 mm.

Pay particular attention to ensuring that

the exhaust air ducts and pipes are kept as short as possible

the pipes are not laid at an acute angle, but as bends and that they are inserted into the shaft at an inclined upward angle and

there are no cross-sectional constrictions in the upward direction (this reduces the volume flow).

As standard, the blow-out opening of the wall hood is in the upward direction.

To pass exhaust air through the outer wall, we recommend the use of our telescopic wall box TM 150-045 (Ø 150).

Note:

To prevent the ingress of water, e.g. condensate or rain water from an uncovered exhaust air shaft, our condensate separator RV 060-150 must be installed in the exhaust air line. The condensate separator must still be acciessible after installation.

Air recirculation

You need the following accessories to install the air recirculation hood:

– KF 600-090: activated charcoal filter:

Depending on the ceiling height, the following duct units are at your disposal for air recirculation:

LK 600-110: Ventilation duct for a ceiling height of 2.39 - 2.60 m

LK 600-120: Ventilation duct for a ceiling height of 2.61 - 3.00 m

The dimensions above refer to a distance of 1.60 m from the floor to the bottom edge of the hood.

Exhaust air operation

Depending on the ceiling height, the following duct units are at your disposal for exhaust air operation:

LK 600-010: Ventilation duct for a ceiling height of 2.27 to 2.60 m

LK 600-020: Ventilation duct for a ceiling height of 2.61 - 3.00 m

The dimensions above refer to a distance of 1.60 m from the floor to the bottom edge of the hood.

If required, a side outlet for the air duct is available at an extra charge.

The socket must be place behind the duct cover on the wall.

522.5

260

150480

air:Exhaust

1400-750

recirculation:Air 1400-825 heightHood

 

 

 

 

 

 

 

 

Sus-

 

 

 

 

 

 

pension

 

 

 

 

2.35air:Exhaust- 3.0 2.43recirculation:Air - 3.0 heightCeiling

 

520

600min.

electricovercooker 670min.

cookergasover

1600

Fig. 17

13

Page 14
Image 14
Gaggenau AH 600-190 manual airExhaust, 1400-750, pension, 600min, cookergasover