6. Assembly instructions

6. Assembly instructions

6.1 Technical data

Weight: 28 kg

Dimensions: 898 x 520 mm

Electrical connection

Pay attention to the rating plate data.

The mains connecting cable must at least correspond to the type H 05 VV-F G 0,75.

When replacing the mains cable, you must dismantle the tubular connection piece (undo 2 screws).

The appliance must only be connected by an authorised specialist. The specialist is respon- sible for perfect functioning of the appliance at its installation location. He must explain the operating principle of the appliance to the user with refe- rence to the operating instructions. He must explain to the user how the appliance can be isolated from the mains whenever required.

Connection possibilities

The extractor hood was conceived for the exhaust air or air recirculation mode. The exhaust air can be routed into a separate exhaust air shaft or directly into the open through the outside wall.

The connector of the connecting cable is connec- ted to the socket that is located behind the duct cover on the wall. If this is not possible, it must be possible to isolate all poles of the appliance from the mains by way of the domestic fuse, or by means of accessible isolating device with a contact gap of at least 3 mm.

AH 600-190

FD xxxx

xxxx

AC 220-240V

50Hz

345W xxxx

160W

35W

3x50W

 

 

 

6.2 Installation

The applicable regulations of the energy supply companies and the regional construction regulations must be observed when installing the hood.

The minimum distance from the worktop to the bottom edge of the wall hood is for electrical appliances 600 mm and for gas appliances 670 mm.

The wall hood was conceived for the exhaust air or air recirculation mode. The exhaust air can be routed into a separate exhaust air shaft or directly into the open through the outside wall.

It is not allowed to pass the exhaust air into a flue or exhaust air chimney that is in operation or into a shaft that is linked to the heating basement. Consult the chimney sweep responsible for your district whenever you wish to pass the exhaust air into a chimney that is not in operation.

During the course of planning, a chimney sweep must be consulted if a room air-dependent hearth is operated in the same room as the one in which a hood is operated in the exhaust air mode. Adequate incoming air must be ensured. The applicable construction and safety regulations must be observed.

Adequate incoming air must be ensured if a wood, coal, gas or oil heater or an open hearth is operated in the same room as the one in which the hood is installed.

Safe operation is possible whenever the partial vacuum in the place where the firing equipment is installed does not exceed 4 Pa (0.04 mbar).

This can be achieved whenever the air needed for combustion is able to enter through openings that cannot be sealed, for example in doors, windows, incoming/exhaust air wall boxes or other technical means.