– Screw together the air guidance housing and

 

 

screw it onto the two retaining brackets (Fig. 25).

 

 

– Establish the pipe connection between the air

 

 

connection piece and the air guidance housing.

 

 

– Establish the electrical connection.

 

 

– Stick the included sealing strips (8 strips) around

 

 

the air slots on the top chimney paneling.

Fig. 25

 

– Remove the protective foil from the chimney

 

paneling.

 

 

 

 

Note: Avoid damaging the sensitive stainless steel

 

 

surfaces.

 

 

– Join the chimney shoe with the chimney base

 

 

using the 6 screws (3.5 x 9.5 mm) (Fig. 26).

 

 

– Fit the top of the chimney into the base. Make

 

 

sure that the fastening holes on the side are at the

 

 

top.

 

 

– Secure the top duct unit with 2 screws on the

 

 

ceiling holder.

 

 

– Pull the shoe down into its final position

 

 

(Fig. 27)

Fig. 26

 

Note: Avoid scratches when fitting the elements

 

into one another by placing the assembly template,

 

 

 

 

for example, over the edge of the bottom chimney

 

 

paneling to protect it.

 

 

– Make sure that an activated charcoal filter is

 

 

installed (see page 10).

 

 

– Reinsert the grease filters.

 

 

– Again screw in the two black plates on the left

 

 

and right of the chimney.

 

 

– Place the glass plates on the black plates.

Fig. 27

 

 

03.6028.63

12.99 SK

17

Page 18
Image 18
Gaggenau AH 600-190 manual Screw together the air guidance housing