For circulating air mode use the installation set

 

For circulating air mode use the installation set

 

included with the ventilation ducts LK 010-112/122

 

und LK 011-112/122. You also need an activated

 

charcoal filter (KF 001-010).

 

 

Proceed as follows:

 

 

– Slightly loosen the screws of the retaining bracket

 

for the chimney paneling. Hang the angle pieces

 

onto the screws and tighten the screws.

 

– Screw the circulating air switch module to the

 

angle pieces (4 screws).

 

 

– Shorten the flexible air pipe accordingly. Fix the

 

flexible air pipe with hose clamps (Fig. 24).

 

– Establish the electrical connection.

 

 

– Stainless steel chimney only (LK 010-112/122):

 

pull the protective film off the chimney’s trims.

 

Note: avoid damaging the sensitive metal surfaces.

 

– Fit the top chimney duct unit into the base. Make

 

sure that the fastening holes on the side are at the

 

top.

 

 

– Put both chimney duct units onto the hood.

 

– Pull the top chimney duct unit up into its final

Fig. 24

position and secure it with 2 screws on the ceiling

holder (Fig. 25).

 

 

 

 

Note: avoid scratches when pulling the elements

 

apart by placing the assembly template, for

 

example, over the edge of the bottom chimney

 

paneling to protect it.

 

 

– Insert the activated charcoal filters.

 

 

– Insert the grease filters.

 

Fig. 25

 

 