Gaggenau AW 230 790 Intense level, Run-on function, Interval ventilation, Lighting, Duration

Models: AW 230 790

1 64
Download 64 pages 13.24 Kb
Page 9
Image 9
Intense level

Intense level

For especially strong odor or vapor, use the intense level.

1Press the ÿ button to switch on the appliance. The fan starts in setting 2.

2Press the Ž button to switch on the Intensive setting.

Note: If the button was pressed while the fan is running on speed 1, 2 or 3, the electronics automatically switch back to the previously- selected fan speed after 5 minutes.

3To switch off the Intensive setting earlier, press the ÿ button or the button for another fan speed.

Setting the duration

You can set the duration after which the Intensive setting switches off automatically.

Duration

Press buttons simultaneously

 

 

3 minutes

Ž and 1

 

 

5 minutes

Ž and 2

 

 

10 minutes

Ž and 3

 

 

The factory setting is set to 5 minutes.

Run-on function

The run-on function can be set for any fan speed.

1First press the button for the desired fan speed 1, 2, 3 or Ž and then press the ž button.

Notes

The run-on time is ten minutes for all fan speed settings. Once this time has elapsed, ventilation switches off automatically.

If the lighting is switched on, it remains on.

2To switch off the run-on function earlier, press the ÿ button.

Interval ventilation

For interval ventilation, the device is switched on automatically for five minutes per hour.

1Press the ÿ button to switch on the appliance. The fan starts at level 2. The interval ventilation can be used on level 1, 2 or 3.

2Press the run-on button ž twice.

Note: This mode is indicated by alternating lighting up of the ž button with the corresponding speed.

3To end interval ventilation, press the ÿ button.

Lighting

The lighting can be switched on and off independently of the ventilation.

Press the @ button.

Setting the brightness

Press and hold the @ button until the desired brightness is reached.

Saturation notification

After 30 hours of operation, the saturation display œ of the grease filter blinks.

At the latest now the metal mesh grease filter should be cleaned. For instructions on how to clean the metal mesh grease filter, please see the chapter about Cleaning and maintenance.

While the saturation display is blinking, it can be reset with the œ button.

9