Gaggenau ED 220, ED221 manual Assembly instructions, Technical data, Installation notes

Models: ED 220 ED221

1 46
Download 46 pages 44.24 Kb
Page 41
Image 41

11. Assembly instructions

11.1 Technical data

Rating: 230 V 1N ~or 400 V 2N ~AC, 16 A

 

Heating power

 

 

Hot air heating element

2700 W

 

Max. water pressure

600 kPa (6 bar)

 

 

 

 

ED 22.-...

FD xxxx xxxx

 

AC 230-240/400-415V 2N 50/60 Hz

2900 W

M 36 W

M 24 W

 

60 W

 

16 A

 

 

 

Technical modifications without notice.

11.2 Installation notes

Pay attention to Chapter 1 (Important notes). The appliance must only be connected by an authorised specialist, paying attention to the relevant regulations of the power supply companies and the regional construction regulations.

Pay attention to the maximum water pressure! Measure the water pressure or inquire with your local authority about the water pressure. Use the correct connection set!

The installing technician is responsible for the correct functioning of the appliance at the time of installation. He must instruct the user on how to operate the appliance correctly on the basis of the Operating Instructions, and the user must be instructed on how to disconnect the appliance in an emergency.

We accept no liability for damage caused by failure to comply with these instructions.

The appliance must always be disconnected from the mains when being repaired or in an emergency. Repairs and maintenance work must be carried out by trained after-sales technicians.

Isolate the appliance from the electric and water mains during every maintenance operation.

To do this, remove the mains plug or actuate the corresponding fuse and turn off the tap.

Electrical connection conditions and water connection information on the rating plate must agree.

The wiring schematic that is adhered to the outer panel of the appliance shows the connection variant again. Do not use any extension leads!

The electrical safety of the appliance is guaranteed only if the earthing system belonging to the domestic installation is installed in accordance with regulations.

The manufacturer is not liable for damage that might arise as the result of improper or non-existent earthing of the appliance.

You can optionally connect the appliance to

230 V 1N ~or 400 V 2N ~by way of a properly installed socket or junction box.

If the appliance is connected to 230V 1N ~, a 16 A fuse must be installed or, if it is connected to 400 V 2N ~, it must be fused with 2 x 10 A.

As standard, the appliance is designed for a rated voltage 230V 1N ~and, in accordance with the rating plate, it can be converted for connection to 400 V 2N .

Insofar as~necessary, the regulations of the local electricity works must be observed. The appliance conforms to EC guideline No. 76/889/EEC in relation to radio interference suppression.

The local electricity supply company regulations, the local kitchen equipment regulations and the installation specifications detailed in DIN 1988, Part 4 and DIN 1986, Part 1 must be observed in relation to connection and operation.

On installation, an isolating device with a contact gap of at least 3 mm (e.g. fuse or LS switch) must be installed.

Pay attention to fire protection regulations in the proximity of heat-sensitive and fire hazard substances.

When connecting the mains lead, you must at least use a cable of the type H05 VV-F 3 x 1.5 mm2.

40

Page 41
Image 41
Gaggenau ED 220, ED221 manual Assembly instructions, Technical data, Installation notes