6. Technical data / Table

Technical data (gas)

 

 

Burners: super strong burner

 

Level 1 low flame

< 850 BTU (0.25 kW)

Level 2 full inner flame

< 1 700

BTU (0.50 kW)

Level 3 small outer flame

 

 

plus level 2 full inner flame3 500

BTU (1.50 kW)

Level 4 full flame

17 000

BTU (5.00 kW)

Gas connection:

R 1/2’’ union nut for R 1/2’’ bracket to DIN 1999, conical-cylindrical

Technical data, gas

Technical data (electrical)

Rated consumption

0.8 W

Voltage

AC 120 V

Frequency

60 Hz

Technical modifications reserved.

Countries

US

US

 

CA

CA

 

 

 

Gas family

Natural gas

Propane gas

Gas type

N

X

Pressure

6” W.C. (1.5 kPa)

10” W.C. (2.5 kPa)

 

 

 

Outer burner, full

170 B

1.10

Outer burner Bypass

0.79

0.57

 

 

 

Inner burner, full

Nr. 44

Nr. 3

Inner burner Bypass

0.44

0.31

 

 

 

 

 

 

Air gap adj / outer [mm]

2

0

Air gap adj / inner

1/2 open

open

 

 

 

∑ Power

17 000 BTU (5 kW)

17 000 BTU (5 kW)

∑ Consumption

0.48 m3/h

364 g/h

12

Page 12
Image 12
Gaggenau Wok manual Technical data / Table