Garland H280 manual Install Extension Fitting if applicable, 3/16” Ferrule

Models: H280

1 23
Download 23 pages 40.12 Kb
Page 7
Image 7
6)Install Extension Fitting (if applicable)

6)Install Extension Fitting (if applicable)

If pilot gas tube going into the valve already has an extension piece (short piece of tubing plus 3/16” brass fitting), unscrew the shorter piece of tubing and proceed to

Step 13. Otherwise, follow these steps to install the proper fitting.

This step must be performed if a TS-11 valve was just removed.

If a Baso valve was uninstalled, cut off 2.5” of the free end of the incoming pilot gas tube to remove the original ferrule and nut and a section of the tubing. If a TS-11 valve was uninstalled, cut off just enough tubing to remove the ferrule.

Refer to the Assembly Drawing included in this manual:

i)Unscrew one end of the 3/16” fitting (Part 4, Assembly Drawing) to release the nut and ferrule. Slide the nut and the ferrule onto the free end of the incoming pilot gas tube.

ii)Insert the remaining portion of the fitting onto the end of the pilot gas tube. Screw on the nut to firmly attach the fitting to the tube. See pictures below for details.

iii)Ensure all connections are leak-proof. Do not over-tighten.

Left: Measure 2.5” from tip of pilot tube and cut

Right: Pilot tube after cutting

Screw this nut onto the fitting to secure the fitting onto the tube

3/16” Ferrule

Extension fitting installed, with nut released to show location of ferrule

03/09/09

P/N 4523367

Page 7

Page 7
Image 7
Garland H280 manual Install Extension Fitting if applicable, Otherwise, follow these steps to install the proper fitting