Part # 4517125 (09/03) Page 7
INSTALLATION
IMPORTANT: Rating plates for this appliance are
located in two places: 1) inside back panel on left side,
2) under front control panel on center.
is equipment must be installed by a competent factory
trained, certified, licensed and / or authorized service or
installation person.
WARNING: is appliance must be properly
grounded.
Prior to installation, the four casters, supplied loose with
the grill, must be securely located on the underside of
the base. e casters fitted with a brake must be located
at the front of the grill.
is appliance should be connected to a potential
equalization system. A labeled equipotential bonding
point is fitted to the rear of the grill.
It is recommended that this grill be connected to a
residual current,, (earth leakage),, device with a tripping
current not exceeding 30mA. e leakage current of this
grill will not exceed 5mA.
CAUTION: Prior to installation, check the electrical
supply to ensure input voltage and phase match the
equipment voltage rating a nd phase. See d ata plate
located rear left side of grill and lower front panel.
Grill is to be located directly under ventilation system.
Once installed in the grill station underneath the
ventilation system, the platens, in their highest position,
must not interfere with the lower lip of the ventilation
system hood. e raised position of each platen is
adjusted by raising or lowering the upper of the two
microswitches, (limit switches), in the rear of the grill.
e lower microswitch position must not be adjusted.
Grill plate must be level front to back, side to side and
diagonally. is leveling must be done with the unit
under the hood and in it’s normal operational position
to prevent warping of the grill plate.
NOTE: Fuses are installed to prevent damage in the
event of failure of the upper microswitch.
National Codes Requirements:
In Cana da, electrical connection must comply with
applicable sections of the Canadian Electrical Code,
C22.1 - 1990, latest edition, “Safety Standard for
Installation, Part 1” and C22.2- No. O-M 1982 latest
edition , “General Requirements, Part 2”.
Electrical Connections:
All electrically operated appliances must be electrically
grounded in accordance with local codes; or in the
absence of local codes, w ith the latest edition of National
Wiring Regulations. A wiring diagram is located on the
rear panel of the grill. See rating plate in rear of grill, or
lower front panel for proper voltages.