Magnum 4K8 Switches Installation and User Guide (10/04)
B4.1 UL Requirements
1.Minimum 14 AWG cable for connection to a Centralized DC power source.
2.Fastening torque of the lugs on the terminal block: 9 inch pound max.
3.Centralized DC Power Source cable securement, use at least four cable ties to secure the cable to the rack at least 4 inches apart with the first one located within 6 inches of the terminal block.
B5.0 OPERATION
Operation of the Magnum Ks with the optional
B6.0 ORDERING INFORMATION
To order the optional
Similarly, to order the optional 24VDC or 125VDC industrial specific power supply factory installed, add a suffix of “ 24VDC” or “125VDC” after the product ‘s
standard model #. Example: Magnum 4K8- 24VDC or Magnum 4K8- 125VDC.
B7.0 TROUBLESHOOTING
Please refer to Section 6.0 for troubleshooting
APPENDIX C: INTERNAL DC
C1.0 SPECIFICATIONS - FOR MAGNUM
DC Power Connector: First Source: “A+”,
GND: | Terminal for “earth” or ground wire connection to the hub chassis | |
Input: | Two separate sources, each at 36 - 70 VDC | |
Power Consumption: | Model | |
Power Supply (Internal, 24VDC | ||
DC Power Connector: First Source: “A+”, | ||
GND: | Terminal for “earth” or ground wire connection to the hub chassis | |
Input: | Two separate sources, each at 20 - 36 VDC | |
Power Consumption: | Model |
Power Supply (Internal, 125VDC
DC Power Connector: First Source: “A+”,
GND: | Terminal for “earth” or ground wire connection to the hub chassis |
Input: | Two separate sources, each at 120 - 160 VDC |
Power Consumption: Model
With the exception of the dual DC input power connections and the power supply, all specifications and configuration options for the Magnum 4K8