Magnum 4K8 Switches Installation and User Guide (10/04)

Step 3. Be sure the pins are precisely aligned with the holes in the header, and the FPM front panel is guided into the front slot cut-out. Then, slowly and carefully apply enough pressure to insert the FPM card pins into position, see Figure 3.4.2b. (If you force the FPM down when the pins are not properly aligned with the holes in the header, the pins will become bent and the FPM is damaged).

Once inserted, the FPM card will be secured by the header connector, the front panel port slot cut-out, and retaining screws.

FPM CARD

MAGNUM 4K-Series Ethernet 10/100 Switch

POWER

SPEED 1

2

3

4

ERROR

L/A

 

 

 

UPLINK

F/H

 

 

 

=X

5 6 7 8

F

H

FPM Empty slot ready for installation

Figure 3.4.2b: Inserting PM Cards into a Magnum 4K8

NOTE: The optional FPM slots need not be filled in order for the Magnum 4K8 unit to be operational. When leaving FPM slots empty, always use a face plate (Magnum FPM-BLNK) to cover the slot opening in the front panel. This will maintain proper cooling air flow, safety, and operation as required by FCC, CE, and other regulations.

Step 4. Once FPM cards have been installed, the chassis cover should be replaced.

3.4.3Removing FPM Cards from Magnum 4K8 Switches

To properly remove an FPM card from a 4K8 Switch, follow the 3 steps below.

Step 1. Remove chassis cover

See procedure in Section 3.4.1 above.

Caution: Be sure the power cord is unplugged.

Attention: Soyez sûr que le cordon de secteur est débranché

Step 2. Remove bottom-front retaining screw for the FPM and Face Plate

On the bottom-front of the unit there is one retaining screws for each FPM card and face plate slot. These screws are used to secure a FPM card in position (see Figure 3.4.3a). Remove the front screw of the FPM to be removed.

www . GarrettCom . com

21

Page 27
Image 27
GarrettCom 4K-Series manual 2b Inserting PM Cards into a Magnum 4K8, Removing FPM Cards from Magnum 4K8 Switches