Magnum 6K25 Managed Fiber Switch

Installation and User Guide (04/06)

The following data has been collected from component manufacturer’s (Agilent’s and Lucent’) web sites and catalogs to provide guidance to network designers and installers.

Fiber

Speed,

 

Std.

Wave

Cable

X’mitr

R’cvr

Worst

Worst*

 

typical

typical*

Port

Std.

Mode

km

-

Size

Output

Sens.

OPB,

distance

 

OPB,

distance

Module

 

fdx

length

m

PT , dB

PR ,dB

dB

Km, fdx

 

dB

Km, fdx

 

 

 

 

 

 

(hdx)

nm

 

 

 

 

 

 

 

 

6KP4-

10Mb

Multi-

2

850

62.5/125

-15.0

-31

14

5

 

17

6

F10ST

FL

Mode

(2)

 

100/140

-9.5

-31

19.5

5.9

 

23.5

7

 

 

 

 

 

50/125

-19.5

-31

19.5

3.4

 

13.5

4.8

6KPM-

100Mb

Multi-

2

1300

62.5/125

-20

-31

9.0

3.0

 

14

5

MST, MSC

FX

mode

(0.4)

 

50/125

-23.5

-31

5.5

2.0

 

12

4

6KPM-SSC

100Mb

Single-

18+

1300

9/125

-15

-31

14

28

 

17.5

35

FX

mode

(0.4)

 

6KPM-

100Mb

Single-

40

1300

9/125

-5

-34

29

58

 

32.5

65

FX

mode

(0.4)

 

SSCL

 

 

 

 

 

 

 

 

 

 

 

 

6KPM-

100Mb

Multi-

2

1300

62.5/125

-20

-31

9.0

3.0

 

15.8

5.5

MTRJ

FX

mode

(0.4)

 

50/125

-23.5

-31

5.5

2.0

 

12.2

4.0

 

 

 

 

 

 

 

 

 

 

 

 

 

6KPM-

100Mb

Multi-

2

1300

62.5/125

-19

-31

12

4

 

16

5.7

FX

mode

(0.4)

 

MLC

 

 

 

 

 

 

 

 

 

 

 

 

6KPM-SLC

100Mb

Single-

15+

1310

9/125

-15

-28

11

22

 

-

-

FX

Mode

(0.4)

 

GBIC-

1000Mb

Multi-

0.55

1300

62.5/125

-9.5

-17

5.5

2

 

12.5

4

 

mode

 

 

SXSC

 

 

 

50/125

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GBIC-

1000Mb

Single-

10

1300

9/125

-9.5

-20

8.5

17

 

10.5

21

 

mode

 

 

LXSC10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GBIC-

1000Mb

Single-

25

1550

9/125

-4.0

-21

15

37.5

 

17.5

43

 

mode

 

 

LXSC25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GBIC-

1000Mb

Single-

40

1550

9/125

-4.0

-21

15

60

 

17.5

70

 

mode

 

 

ZXSC40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GBIC-

1000Mb

Single-

70

1550

9/125

-3.0

-23

18

90

 

20.5

102

 

mode

 

 

ZXSC70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed over long distances (i.e., in excess of approx. 400 meters) can be achieved only if the following factors are both applied:

The 100Mb fiber segment must operate in full-duplex (FDX) mode, i.e. the full-duplex (factory default) setting for 100Mbps fiber ports must be used, and

The worst-case OPB of the fiber link must be greater than the fiber cable’s passive Attenuation.

(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)

www . GarrettCom . com

40

Page 47
Image 47
GarrettCom 6K25 manual 6KP4, ’cvr