CHAPTER 4: Installing Components

7Align the new power distribution board with the stand-off and locking tabs on the chassis, then place it on the stand-offs and slide it toward the side of the chassis until the tab clicks into place.

8Replace the screw you previously removed.

9Reconnect the power cables. See “System board” on page 4 for the location of the connectors on the system board.

10Reinstall the power supply modules by following the instructions in “Replacing a power supply module” on page 46.

11Follow the instructions in “Closing the server case” on page 30.

Replacing the power cage

To replace the power cage:

1Follow the instructions in “Preventing static electricity discharge” on page 28. Make sure that you turn off the server, then unplug the power cord(s) and all other cables connected to the server.

2Follow the instructions in “Opening the server case” on page 29.

3Remove the power supply modules by following the instructions in “Replacing a power supply module” on page 46.

4Remove the power distribution board by following the instructions in “Replacing the hot-swap backplanes” on page 49.

5Loosen the screws (3) holding the power cage in the chassis.

48