CHAPTER 4: Installing Components

3Press the retaining clip (1) on the power supply to the left to release the power supply module (2) from the chassis.

4Using the handle, pull the power supply module straight out of the server. It may take considerable force to remove.

5Push the new power supply module into the server, with the retaining clip on the right, until it locks into place.

6Reconnect the AC power cord for the new power supply module.

Replacing the power distribution module

To replace the RPS power distribution module:

1Follow the instructions in “Preventing static electricity discharge” on page 24. Make sure that you turn off the server, then unplug the power cord(s) and all other cables connected to the server.

2Follow the instructions in “Opening the server case” on page 25.

3Remove the PCI riser assembly by following the instructions in “Installing and removing PCI expansion cards” on page 34.

4Remove the fan duct and system fan cage by following the instructions in “Replacing system fans” on page 38.

5Disconnect the main power, CPU power, backplane power, I2C power, and midplane power cables from the system board. See “System board” on page 5 for the location of the connectors on the system board.