Installation Instructions

INSTALLING THE WATER LINE (ICEMAKER & DISPENSER MODELS)

BEFORE YOU BEGIN

 

WHAT YOU WILL NEED

Recommended copper water supply kits are WX8X2,

 

 

 

WX8X3 or WX8X4, depending on the amount of tubing

 

 

 

you need. Approved plastic water supply lines are GE

 

 

 

SmartConnectRefrigerator Tubing (WX08X10006,

 

 

 

WX08X10015 and WX08X10025).

 

• Copper or GE SmartConnectRefrigerator

When connecting your refrigerator to a GE Reverse

 

Tubing kit, 1/4outer diameter to connect the

Osmosis Water System, the only approved installation

 

refrigerator to the water supply. If using copper,

is with a GE RVKit. For other reverse osmosis water

 

be sure both ends of the tubing are cut square.

systems, follow the manufacturer’s recommendations.

 

To determine how much tubing you need:

If the water supply to the refrigerator is from

 

measure the distance from the water valve on

a Reverse Osmosis Water Filtration System

 

the back of the refrigerator to the water supply

AND the refrigerator also has a water filter,

 

pipe. Be sure there is sufficient extra tubing to allow

use the refrigerator’s filter bypass plug. Using

 

the refrigerator to move out from the wall after

the refrigerator’s water filtration cartridge in

 

installation.

 

conjunction with the RO filter can result in hollow

 

GE SmartConnectRefrigerator Tubing Kits are

ice cubes and slower water flow from the water

 

available in the following lengths:

dispenser.

 

6(1.8 m)

– WX08X10006

This water line installation is not warranted by

 

 

15(4.6 m) – WX08X10015

the refrigerator or icemaker manufacturer. Follow

 

25(7.6 m) – WX08X10025

these instructions carefully to minimize the risk

 

 

 

of expensive water damage.

 

 

 

Water hammer (water banging in the pipes) in

 

 

 

house plumbing can cause damage to refrigerator

 

 

 

parts and lead to water leakage or flooding. Call a

 

 

 

qualified plumber to correct water hammer before

 

 

 

installing the water supply line to the refrigerator.

 

 

 

To prevent burns and product damage, do not hook

 

 

 

up the water line to the hot water line.

 

 

 

If you use your refrigerator before connecting

 

 

 

the water line, make sure the icemaker power

 

 

 

switch is in the O (off) position.

 

 

 

Do not install the icemaker tubing in areas where

 

 

 

temperatures fall below freezing.

 

 

 

When using any electrical device (such as a power

 

 

 

drill) during installation, be sure the device is double

 

 

 

insulated or grounded in a manner to prevent the

 

 

 

hazard of electric shock, or is battery powered.

 

 

 

All installations must be in accordance with local

 

 

 

plumbing code requirements.

 

 

 

 

 

 

 

32

Page 32
Image 32
GE 200D8074P050 installation instructions Copper or GE SmartConnect Refrigerator

200D8074P050 specifications

The GE 200D8074P050 is a sophisticated component renowned for its reliability and performance in various industrial applications. As part of General Electric's extensive lineup of products, this unit exhibits a range of features and technologies designed to meet the stringent demands of modern electrical systems.

One of the standout characteristics of the GE 200D8074P050 is its robust construction aimed at ensuring durability and longevity. Built with high-quality materials, this component is engineered to withstand challenging operating conditions, making it suitable for heavy-duty industrial environments. Its durability is complemented by its efficient thermal management capabilities, which allow for stable performance even under significant load conditions.

Another notable feature is its advanced electrical characteristics. The GE 200D8074P050 is designed for optimal efficiency with a well-balanced power handling capacity. This translates to lower operating costs and reduced energy consumption, aligning with contemporary standards for sustainability and environmental responsibility. Furthermore, the unit has excellent voltage regulation technologies, ensuring minimal fluctuations and enhancing the reliability of the entire electrical system.

The integration of cutting-edge technologies is a hallmark of the GE 200D8074P050. It often includes features such as digital control mechanisms and real-time monitoring capabilities, facilitating easier diagnostics and maintenance. These technologies not only enhance operational efficiency but also improve safety by quickly identifying potential issues before they escalate into more serious problems.

The GE 200D8074P050 is also designed with adaptability in mind. It can be seamlessly integrated with existing systems, providing versatility across a wide range of applications, from manufacturing to power generation. Additionally, the component is compliant with various industry standards, which assures users of its reliability and performance consistency.

In summary, the GE 200D8074P050 exemplifies a blend of quality, technology, and performance. With its rugged design, efficient power handling, advanced monitoring capabilities, and adaptability, it stands out as an essential component for industries looking to enhance their operational effectiveness while maintaining high standards of safety and reliability. As industrial settings continue to evolve, the integration of components like the GE 200D8074P050 will be crucial in driving efficiency and performance.