Installation Preparation – Drain

PREPARE DRAIN PLUMBING

Drain Requirements

Follow local codes and ordinances.

Drain hose must not exceed 10 feet in length.

A high drain loop or air gap is required. See below.

Drain Method

The type of drain installation depends on the following:

Do local codes or ordinances require an air gap?

Is waste tee less than 18" above the floor?

If the answer to either question is YES, an air gap (Method 1) must be used. If both answers are NO, either an air gap or a high drain loop (Method 2) may be used.

Special consideration for a dishwasher installed on a pedestal

lf the dishwasher is installed on an elevated platform, a high drain loop of at least 32" above the platform must be provided in addition to the air gap requirement determined above. This is necessary for proper drain performance.

CAUTION

An air gap MUST BE USED if the drain hose is connected to waste tee or disposer lower than 18" above the floor level. Failure to provide the proper drain connection height with an air gap or 32" minimum, high drain loop will result in improper draining of the dishwasher, which may cause damage.

PRECAUCIÓN

SE DEBE USAR un espacio de aire si la manguera

de drenaje se conecta a la T de desechos o al triturador menos de 18" por encima del nivel del piso. No disponer la altura correcta de la conexión del drenaje con

un espacio de aire o 32" de mínimo, una curva alta de drenaje resultará en un drenaje incorrecto

de la lavadora, lo que pude causar daños.

METHOD 1 – Air Gap with Waste Tee or Disposer

 

Figure C

Waste Tee Installation

Disposer Installation

METHOD 2 – High Drain Loop with Waste Tee or Disposer

Provide a method to attach the drain hose to the underside of countertop. Attachment will be made in a later step.

32"

32"

Min.

18" Min.

18"

Min.

Min.

 

 

Figure D

Waste Tee Installation

Disposer Installation

Install waste tee or disposer and the air gap according to the manufacturer’s instructions.

Cabinet Preparation

Drill a 1-1/2" diameter hole in the cabinet wall within the shaded area shown in Figure A for the drain hose. Make sure there are no sharp edges. The drain hose will be passed through this hole and connected to the drain in a later step.

IMPORTANT When

 

Remove

 

connecting the drain line to a

 

 

 

Drain

disposer, check to be sure that

 

 

Plug

drain plug has been removed.

 

 

 

Dishwasher will not drain if

 

 

plug is left in place.

 

 

4

Page 4
Image 4
GE 206C1559P195 installation instructions Installation Preparation Drain, Important When, Prepare Drain Plumbing

206C1559P195 specifications

The GE 206C1559P195 is a component that belongs to General Electric's suite of high-performance aircraft engine components. Specifically, this part is integral to the Geared Turbofan (GTF) engine technology that GE has pioneered, aiming at increasing fuel efficiency while reducing noise and emissions.

One of the standout features of the GE 206C1559P195 is its advanced aerodynamic design, which plays a crucial role in optimizing the engine's performance. The component helps improve air flow, thereby enhancing thrust and operational efficiency. By utilizing sophisticated Computational Fluid Dynamics (CFD) simulations in its design process, GE has ensured that the part meets the rigorous demands of modern aviation.

The GE 206C1559P195 also incorporates cutting-edge materials technology. Constructed with lightweight yet robust materials, the part significantly contributes to the overall weight reduction of the engine, which is vital for maximizing fuel efficiency. The use of composite materials and advanced alloys ensures that the component can withstand extreme temperatures and pressures associated with high-performance engine operation.

Another characteristic that sets the GE 206C1559P195 apart is its reliability and durability. GE's stringent manufacturing processes and quality control protocols ensure that each component is built to last, reducing maintenance frequency and enhancing operational reliability. The part is designed to have a long service life, making it a cost-effective choice in the long run for airlines and operators.

In terms of technological innovation, the GE 206C1559P195 features integrated sensors that provide real-time data on engine performance. This capability allows for better monitoring and predictive maintenance, thereby increasing safety and reducing unscheduled downtimes.

Furthermore, the integration of digital twin technology enables operators to simulate different operational scenarios, improving decision-making and optimizing maintenance schedules. This technological edge places the GE 206C1559P195 at the forefront of aircraft engine component innovations, aligning with the industry's shift toward sustainability and efficiency.

In summary, the GE 206C1559P195 is a remarkable component that embodies GE's commitment to advance aviation technology, emphasizing performance, durability, and environmental awareness. Its design and technological features reflect the ongoing evolution in the aerospace industry, making it a key asset for modern aircraft engines.